General Chemistry
Albumin
Bilirubin, Direct
Bilirubin, Total
Calcium
Carbon Dioxide
Creatinine
Glucose
Iron, Total
Magnesium
Phosphorus
Protein, Total
Urea Nitrogen (BUN)
Uric Acid
Enzymes
Alanine Amino Transferase (ALT)
Alkaline Phosphatase
Amylase
Aspartate Transaminase (AST)
Creatine Phosphokinase (CPK)
Gamma Glutamyl Transferase (GGT)
Lactate Dehydrogenase (LDH)
Lipids
Direct LDL
Triglycerides
Direct HDL
Cholesterol
Electrolytes
Chloride
Potassium
Sodium
In Development
CRP Wide Range
CRP High Sensitivity
Digoxin
Ferritin
Fructosamine
Hemoglobin A1c
Lipase
Microalbumin
Phenobarbital
Phenytoin
Theophylline
UIBC
Technical Specifications
| Ion-selective electrodes | Na+, K+, Cl- |
| Throughput per hour | 180 with ISE |
| Number of sampling arms | 1 |
| Methodologies on line | Up to 60 |
| Dimensions | 30"Lx29"Wx25.5"H |
| Sample positions | 9 |
| Pediatric sample | Programmable |
| Stat sample | Yes |
| Calibrators | Programmable |
| Controls | Programmable (Levey-Jennings Graph / 3-levels) |
| Positive sample identification | Yes – with integrated barcode reader |
| Sample primary tube types | 12-13 mm diam / 75-85 mm height |
| Dead Volume | 100 μl – 12-13 mm primary tube 50μl – 3mL sample cup |
| Sample size | 2 - 100 μl – minimum maximum |
| Sample dilution | Pre-dilution |
| Automatic std. curve dilution | Yes – up to 8 points |
| Diluter | Micro-metering pump |
| Liquid level sensor | Yes – capacitive |
| Crash detection | Yes |
| Sample type | Plasma, serum |
| Cuvettes on board | 80 (re-washable) |
| Cuvettes type | Optical plastic |
| Incubation heater | 37°C ± 0.1°C controlled |
| Cuvette washing station | Yes |
| Reagent positions | 28 |
| Positive reagent Identification | Yes – with integrated barcode reader |
| Reagent bottles | 25ml and 14ml |
| Reagent Volume (μl) | 180 - 300 μl – minimum maximum |
| Diluter | Micro-metering pump |
| Liquid level sensor | Yes – capacitive |
| Shock sensor | Yes |
| Maximum N° of reagents/test | 3 |
| Reagent cooling | Yes |
| Multiple rgnt. position (same lot) | Yes |
| Analytical methods | End-point, bichromatic end-point, fixed-time, kinetic, differential sample blank, differential 2-reagents |
| Photometer type: light source | Halogen lamp |
| Type of measurement | Mono or bichromatic |
| Wavelengths | 340-700nm |
| Photometric linearity | 0-3 O.D. |
| Wash consumption | Up to 2 liters/hour |
| System solutions | Systemic solution & cleaner solution |
| Deionized water supply | No |
| Operating system | Windows XP® |
| LIS connection | Yes |
| Patient archive | Yes – up to 15,000 patients |
| Q.C. archive | Yes – up to 5,000 tests |