Product OverviewSoftwareTech Specs and Test MenuContact

General Chemistry
Albumin
Bilirubin, Direct
Bilirubin, Total
Calcium
Carbon Dioxide
Creatinine
Glucose
Iron, Total
Magnesium
Phosphorus
Protein, Total
Urea Nitrogen (BUN)
Uric Acid

Enzymes
Alanine Amino Transferase (ALT)
Alkaline Phosphatase
Amylase
Aspartate Transaminase (AST)
Creatine Phosphokinase (CPK)
Gamma Glutamyl Transferase (GGT)
Lactate Dehydrogenase (LDH)

Lipids
Direct LDL
Triglycerides
Direct HDL
Cholesterol

Electrolytes
Chloride
Potassium
Sodium

In Development
CRP Wide Range
CRP High Sensitivity
Digoxin
Ferritin
Fructosamine
Hemoglobin A1c
Lipase
Microalbumin
Phenobarbital
Phenytoin
Theophylline
UIBC

Technical Specifications


General
Ion-selective electrodes Na+, K+, Cl-
Throughput per hour 180 with ISE
Number of sampling arms 1
Methodologies on line Up to 60
Dimensions 30"Lx29"Wx25.5"H

Sample System
Sample positions 9
Pediatric sample Programmable
Stat sample Yes
Calibrators Programmable
Controls Programmable (Levey-Jennings Graph / 3-levels)
Positive sample identification Yes – with integrated barcode reader
Sample primary tube types 12-13 mm diam / 75-85 mm height
Dead Volume 100 μl – 12-13 mm primary tube
50μl – 3mL sample cup
Sample size 2 - 100 μl – minimum maximum
Sample dilution

Pre-dilution
Post-dilution / rerun

Automatic std. curve dilution Yes – up to 8 points
Diluter Micro-metering pump
Liquid level sensor Yes – capacitive
Crash detection Yes
Sample type Plasma, serum

Cuvette System
Cuvettes on board 80 (re-washable)
Cuvettes type Optical plastic
Incubation heater 37°C ± 0.1°C controlled
Cuvette washing station Yes

Reagent System
Reagent positions 28
Positive reagent Identification Yes – with integrated barcode reader
Reagent bottles 25ml and 14ml
Reagent Volume (μl) 180 - 300 μl – minimum maximum
Diluter Micro-metering pump
Liquid level sensor Yes – capacitive
Shock sensor Yes
Maximum N° of reagents/test 3
Reagent cooling Yes
Multiple rgnt. position (same lot) Yes
Analytical methods End-point, bichromatic end-point, fixed-time, kinetic, differential sample blank, differential 2-reagents

Measurement System
Photometer type: light source Halogen lamp
Type of measurement Mono or bichromatic
Wavelengths 340-700nm
Photometric linearity 0-3 O.D.

Wash System
Wash consumption Up to 2 liters/hour
System solutions Systemic solution & cleaner solution
Deionized water supply No

Software
Operating system Windows XP®
LIS connection Yes
Patient archive Yes – up to 15,000 patients
Q.C. archive Yes – up to 5,000 tests
For more information, or to contact your local sales rep, please click here or call 1.800.783.1539.